UPS Kehua KR RM Rack/Tower Series 1-15kVA

UPS Kehua KR RM Rack/Tower Series 1-3kVA for back up computer room, data center, precision instrument, intelligent device, auto manufacturing, glass & metallurgy industry, PLC system, Petrochemical Industry, Automation Equipment, and Power Plants.

UPS Kehua KR RM 1-3 for Hospital, Data Center, Restaurants, Servers, Power Plants, Etc
Excellent Flexibility Value for Investment
  • Output voltage and ECO mode are selectable via LCD
  • 1~8A charging current settable via software (6-10KVA)
  • Batteries quantities are settable (16/17/18/19/20 for 6-10kVA)
  • Maintenance bypass for 6-10kVA (option)
  • Battery disconnection alarm (option)
  • SNMP or RS485+dry contact (option)
  • Charging voltage temperature compensation (option)
  • Input power factor up to 0.996, low THDi (< 5%), decrease pollution to city power
  • AC/AC efficiency up to 95%, energy saving and low carbon emission
  • Compliance with RoHS standard, innocuous and environmentally friendly
  • Design in accordance with International EMC and Safety standard

Outstanding Profitability Features
Minimium 0.05m2 footprint, save delivery cost and easy for installation
  • IP65 level of protection, for Outdoor and Indoor use
  • Cutting edge design and technology
  • High quality components maximize service life
  • Full Alarm and protection design
  • Uninterrupted power supply
ModelKR1000−RMKR2000−RM KR3000-RM KR15.000-RM
Input
Voltage (VAC)120~295138~485 (L:L)
Frequency (Hz)40~7040~70
Power Factor≥0.99
THDi<4% <3% (linear load)
On-grid Output
Capacity (VA)10002000300015.000
Max. AC/AC Efficiency92.5%93.5%93.8%96%
Power Factor>0.99 0.9 (1.0 at 40°C)
Voltage (VAC) 208/220/230/240±1% (selectable on display panel)380/400/415±1% (L-L)
Frequency (Hz) 50/60±0.1% (battery mode)50/60±0.1 (battery mode)
THDv THD < 2% (linear load); THD < 3% (nonlinear load) THD <2% (linear load)
THD < 4% (nonlinear load)
Transfer Time (ms)00
Battery
Voltage (Standard)(Vdc)367272 ±192 (±144~±240 adjustable) / 32 pcs default (28−40 pcs adjustable)
Battery Type3×12V 7Ah/External4×12V 9Ah/External6×12V 9Ah/External
Max. Charger Current (A)1 (Standard)/4 (Long backup
Other
Communication InterfaceRS232, EPO, USB (slot) (SNMP, RS485+dry contact are optional in slot) RS485+EPO (RS232+Dry contact, SNMP are optional in slot)
LCD Display AC input & output voltage, frequency, Load level, battery level, temperature; AC mode, battery mode, bypass mode, and faulLCD
Alarm Low battery, abnormal AC input, UPS failure, etc. Low battery, abnormal AC input, UPS failure, etc.
ProtectionLow battery, overload, short-circuit and over temperature, etc Low battery, overload, short-circuit and over temperature, etc.
Noise (dB)<40 <55
Relative Humidity 0~95%, no condensation 0~95%, no condensation
Dimension (WxDxH) 145×360×225190×400×330 438×500×130(3U)
Weight With Battery (Kg)9.2/11.6 17.7/22.422.9/27.620
Weight Long Backup (Kg)4.58.5 9.28